50 HZ: 1550 – 3400 KVA


MTU 4000 DS

MTU 4000 series generator sets perform at the highest level and cover the power range from 1125 to 3250 kWe (1550 to 3400 kVA). With a robust design and optimal fuel consumption, our diesel generator sets are trusted by customers around the world.

  • Verified product design, quality and performance integrity
  • Cutting-edge emissions control
  • Superior on-site specific de-rating behavior due to state-of-theart engine controller with engine site condition management system
  • Compliant with industry codes & standards
  • The generator set fulfills performance per ISO 8528 and offers 100% load acceptance according to NFPA 110
  • Permanent magnet excitation system for generator as standard for improved transient response
  • Best-in-class reliability and availability
  • Optimized maintenance intervals
  • Fullfil worldwide certifications: ISO 8528, CE/IEC, UL2200, NFPA 110, IBC2009, German Grid Code
  • Uptime Inst. Compliant: Tier I, II, III, IV

Icon_F_Load_02

INDUSTRY LEADING LOAD FACTOR

85% load factor for standby applications and 75% load factor for prime power applications

Icon_ISO_02

ISO DESIGNED AND MANUFACTURED

Our facilities are certified to standards ISO 9001:2008 and ISO 14001:2004

Icon_Monitor_02

ADVANCED MONITORING & COMMUNICATIONS

Wide range of applications available from island operation to mains parallel operation

PRODUCT LIST FOR MTU 4000 DS

PRODUCT

STANDBY APPLICATIONS

PRIME APPLICATIONS

Standby Power Standby Power with Overload Data Center Continuous Power Mission Critical Power Prime Power Grid Stability Power
MTU 12V4000 DS1650 1700 kVA 1550 kVA 1550 kVA 1550 kVA 1550 kVA 1550 kVA
MTU 12V4000 DS1750 1800 kVA 1650 kVA 1650 kVA 1650 kVA 1650 kVA 1650 kVA
MTU 12V4000 DS2000 2000 kVA 1850 kVA 1850 kVA 1850 kVA 1850 kVA 1850 kVA
MTU 16V4000 DS2250 2300 kVA 2100 kVA 2100 kVA 2100 kVA 2100 kVA 2100 kVA
MTU 16V4000 DS2500 2600 kVA 2250 kVA 2250 kVA 2250 kVA 2250 kVA 2250 kVA
MTU 20V4000 DS2750 2700 kVA 2600 kVA 2600 kVA 2600 kVA 2600 kVA 2600 kVA
MTU 20V4000 DS3100 3200 kVA 2850 kVA 2850 kVA 2850 kVA 2850 kVA 2850 kVA
MTU 20V4000 DS3300 3400 kVA 3100 kVA 3100 kVA 3100 kVA 3100 kVA 3100 kVA

OPTIONS FOR MTU 4000 DS

  • Emissions

    EPA Tier 2; TA-Luft optimized; fuel consumption optimized

  • Generator

    Multiple generator models and voltages available; anti-condensation heaters; winding temperature sensors; bearing temperature sensors; differential protection current transformers; digital voltage regulator

  • Cooling System
  • Control Panel

    Wide variety of control panel configuration; full range of applications from island operation to mains parallel operation of multiple gensets; various expansion modules (analog and digital in- and outputs) for controller

  • Fuel System

    Fuel pre-filters with water separators

  • Exhaust system

    Silencers from varying sound attenuation levels